This current-to-voltage signal processing module requires a separate operating power supply during operation. In the process of control signal transmission, the voltage signal will attenuation with the increase of the transmission distance, the use of current transmission can avoid the signal attenuation. This module is used for the end of the current signal transmission to convert the current signal into a voltage signal and a signal detection unit.

Working power supply: DC7-30V;

Input signal: 4-20mA;

Output signal: 0-5V;

If you for any reason are not happy with any product supplied , please do not hesitate to contact us and we will do our best to solve your problem .

Description

Description:
This current-to-voltage signal processing module requires a separate operating power supply during operation.
In the process of control signal transmission, the voltage signal will attenuation with the increase of the transmission distance, the use of current transmission can avoid the signal attenuation.
This module is used for the end of the current signal transmission to convert the current signal into a voltage signal and a signal detection unit.

Parameter:
Working power supply: DC7-30V;
Input signal: 4-20mA;
Output signal: 0-5V;
Temperature drift: 100ppm / ;
Ambient temperature: -10-60 ;
Storage temperature: -20-85 ;
Atmospheric pressure: 86-106KPa;

Debug Description:
1. Wiring according to the wiring diagram, pay attention to positive and negative.
2. Adjust the minimum value: input (IN), input 4mA current signal, adjust the ZERO potentiometer with the tool, so that "Vout" voltage output is 0V;
3. Adjust the maximum value: input (IN), input 20mA current signal, adjust the SPAN potentiometer with the tool, so that "Vout" voltage output is 5V;

Precautions for use:
1. The input and output of the positive and negative can not be connected to the wrong, otherwise it will damage the module.
2. After installation, you must check whether the wiring is correct and confirm that the wiring is correct before you can use it.

Package Included:
1*4-20mA To 0-5V Current - To - Voltage Signal Processing Module

https://www.lemande.com/ is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to amazon.com, amazon.co.uk, amazon.ca, endless.com, smallparts.com, myhabit.com, and any other website that may be affiliated with Amazon Service LLC Associates Program.